Hyun-Woo Sim, June-Seok Lee, and Kyo-Beum Lee, "Detecting Open-Switch Faults: Using Asymmetric Zero-Voltage Switching States," IEEE Industry Applications Magazine, vol. 22, no. 2, pp. 27-37, Mar.-Apr. 2016.

2016
PEEMS
  • Oct. 4, 2023

views
1. Authors: Hyun-Woo Sim, June-Seok Lee, and Kyo-Beum Lee
2. Title: Detecting Open-Switch Faults: Using Asymmetric Zero-Voltage Switching States
3. Journal: IEEE Industry Applications Magazine
4. Vol/no/pp: vol. 22, no. 2, pp. 27-37
5. Date: Mar.-Apr. 2016
6. Abstract
: This article presents a detection method for an open-switch fault in cascaded H-bridge multilevel inverters (CHMIs). Recently, CHMIs were widely used in high-power systems. Therefore, the reliability of this topology has become an important factor. To improve the reliability, methods for detecting open-switch faults are required. The proposed method is based on the current path analysis according to zero-voltage switching states. The location of both faulty cells and switches can be detected from the current waveform and zero-voltage switching states. This method is applicable when using the level-shifted pulsewidth modulation (LSPWM), which is commonly used for a modulation method in CHMIs. The performance of the proposed detection method is verified by simulation and experimental results.